OpenPlant Modeler Help

To Place HVAC Inline Components

  1. Open the Standard Preferences dialog and set the HVAC System and component values.
    Note: By default, only the Insulation Thickness and Insulation Material component properties are displayed.
  2. Select an inline component (Dampener, Silencer) option from the Inline Devices gallery.
    Note: Select an inline component (Dampener, Silencer) option from the HVAC taskbar.
  3. Pick one of the following Placement Points for the duct in the Place Component dialog:

    Main Port

    or

    Run Port

  4. Expand the HVAC Port Settings tab and define the options available for the port end preparations.
  5. Click the Design Conditions to define the size parameters for the length of duct. (Width, Height, etc.)
  6. Select a run of HVAC duct in which to place the inline component. An outline of the component displays.
  7. Use the mouse to determine the placement point within the run and left-click to finalize the location.
  8. Right-click to complete the procedure.